Human machine interface factory by mochuan-drives.com: Interaction design is subordinate to the product system and is a strong support and refinement to successful product design. If we use the system theory point of view, interaction design is a subsystem of the product design system. Design Principles: The following principles should be considered for the design of human machine interface. The basic user-centered design principle: In the design process of the system, designers should grasp the characteristics of users and discover the needs of users. Users’ opinions should be constantly sought and consulted throughout the development process of the system. The design decisions of the system should be integrated with the users’ work and application environment, and the users’ requirements for the system must be understood. The best way is to involve real users in the development, so that developers can properly understand the needs and goals of users, and the system will be more successful. Find more details at hmi touch screen.
Selecting the installation method: The installation mode of plc system is divided into centralized, remote i/o and distributed with multiple plc networking. Centralized hardware does not need to be set to drive remote i/o hardware, the system response is fast and cost is low; Remote I/O type is suitable for large systems, the system device distruibution range is very wide, remote i/o can be scattered installed near the field device, the connection is short, but need to add drivers and remote i/o power supply; The distrbuted network of multiple plc is suitable for the occasions where multiple devices are independently controlled and interconnected, and small plc can be selected, but communication module must be attaced.
Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects.
The Fourth Step: Communication Mode Preference is given to the HMI Panel itself with lower computer drive touch screen. Firstly, this is will be more convenient and simple in the definition of the subsequent project address and conversion, becuase if you choose Modbus compatible devices, it is necessary to convert the HMI touch screen monitoring address according to the rules of the definition of different lower computer(PLC) manufacturer, which not only greatly increase the workload of engineers and also easy to covert the wrong. Secondly, needing to draw up in advance, a communication program for the entire project. Do it need the ethernet to communicate with the upper computer, or need two rs485 to be maste or slave station communication, or through one rs485 and one rs232 communication to achieve.
Less performance used to match a very high cost, so will it worth? And where is your market point? Maybe more consider another China brand with a very perfect performance too, such as Mochuan brand. Welcome contact us to discuss more. The Second Step: Selecting The HMI Screen Size There are two means of size here. One is screen display screen size, the other is CPU size. Integrating the scale of the entire project, to determine the size of the HMI panel needs, through the project as a whole to present the effect. Do not select the size is too small or too large, becuase too small is look very compact and not enough to operate in well, too large will look the overall proportion of the untuned and waste. It requires engineers to design a good enginnering diagram in advance to allocate the size of each accessory part of the proportion. Wanna win every high value market, it needs to pre-design and seriously selected, but not take for granted. Discover extra info at https://www.mochuan-drives.com/.
Use a multimeter to determine the test wiring according to the pins in the wiring diagram. Verify that the RS485 and RS232C wiring is correct, touch screens differ from various PLC wiring. This can be viewed by referring to Maintenance Control (help documentation for PLC and touch screen communication line connections), which is the basic method for normal troubleshooting of communication problems. Next I show you how to bypass the touch screen problem – online simulation. When communication fails, some customers will guess that there may be a problem with the touch panel interface or a problem with the interface. Online simulation means bypassing the touch screen and using the PLC to connect directly to the computer. Using our configuration software, the communication cable from the PLC itself is connected to the computer and an online simulation is carried out to see if the project can communicate. This can be done with a numerical input element or switch to see if the operation before and after closing the simulator and opening the online simulation is still present and if it prompts a direct NC (NC and previous operations not written down are not connected).
This type touchscreen panel support 7inch, 9.7inch, 17inch, 22inch and 32inch, is enough to select suitable model for the project from application and cost. There are two operating temperature -10°C to 60°C and -20°C to 70°C. And all the size and model is to support ethernet, 2pcs rs485 or 2pcs rs232 is in optional. Adpoting industrial grade high quality components, high protection level design, comprehensive three-proof coating, no matter the wet underground mine, high temperature gobi or corrosive gas, oil mist or dust factory environment, can easily cope with, easy to handle.
The size range is 4.3inch, 7inch, 9.7inch, 10.1inch, 12inch and 15inch, with ethernet, RS485, RS232 and RS422 to meet different application using. If you have the requirement of HMI, it is good to description of your application and what function wanna realize, then the correct and the most suitable model will be recommended to you. Mochuan Drives offers three series of plc programmable logic controller, there are switch control and motion control with very strong power for choosing. Offering free software, demo, 36months warranty, mature solution. And one-to-one technical supporting online to fast solve the customer technical question. Supporting to take the video to solve the technical question, that is service do you need?
At the same time, because the electrical room has the characteristics of complex data processing, many inverters, strong voltage interference, and closed space, the requirements for the configuration, stability, and anti-interference of the body are high. The industrial-grade control equipment can be well integrated into the electrical cabinet control equipment, and can effectively control all electrical equipment, in the current era of big data and the Internet of Things, and even directly through remote control equipment, the electrical cabinet equipment monitoring.
Human-Computer Interaction (HCI): The science of designing, evaluating, and implementing interactive computing systems for use by people and the study of these phenomena. HCI and human-computer interface are two concepts that are closely related but not identical. The RelationShip Between Human Computer Interaction and HMI: Human-computer interaction is the interaction between a human and a machine, which is essentially the interaction between a human and a computer. Or from a broader perspective: HCI refers to the interaction between a human and a machine containing a computer.