Core cutting line manufacturer factory with canwindg.com: Power Quality and Distribution Transformers – The efficiency of distribution transformer substations is significantly affected by power quality. These transformers, which are critical components of the electrical distribution system, convert high-voltage electricity into lower voltage levels suitable for end-use applications. The performance and efficiency of these transformers largely depend on the quality of power they receive. Poor power quality, characterized by voltage sags, swells, harmonics, and flicker, can lead to increased losses in power distribution transformers. These losses can be categorized into two types: core losses and copper losses. Core losses occur due to variations in the magnetic field within the transformer’s core, while copper losses occur due to the resistance of the transformer’s windings. Both these losses are exacerbated under conditions of poor power quality, leading to decreased efficiency of the transformer. Discover additional information on slitting line manufacturers.
Insulation level: The insulation level of a transformer refers to the insulation performance of the transformer at the time of design. For example, a 220kV transformer means that the designed insulation voltage of the transformer is 220 kV. Cooling method: The cooling method of the transformer refers to the heat dissipation method of the transformer. For example, transformers can dissipate heat through natural cooling, forced air cooling, or forced water cooling. To sum up, the rated value on the transformer nameplate refers to some important electrical parameters and performance indicators of the transformer, which is of great significance for the selection, installation and operation of the transformer.
The efficiency of the transformer refers to the energy conversion efficiency of the transformer, that is, the ratio of the output power to the input power. Improving the performance of transformers can reduce energy loss and energy consumption, thereby improving the economy and reliability of transformers. Here are a few ways to improve transformer performance: Optimizing transformer design: When designing a transformer, optimized design methods can be used, such as reducing the reluctance of the iron core and winding, reducing copper loss and iron loss, etc., thereby reducing the energy loss of the transformer and improving performance. Choose high-quality materials: When manufacturing transformers, you can choose high-quality materials, such as low-loss silicon steel sheets, high-conductivity materials, etc., to reduce material loss and energy consumption and improve performance.
CANWIN is not just a length lines company, but also electrical equipment manufacturer. It is the legend of people who have forged their lives with faith and action. CANWIN electrical machinery equipment manufacturing deploys an innovation chain through the industrial chain.Equipment sales can provide integrated solutions; can provide OEM/ODM services to global transformer manufacturers; can provide raw material supply to transformer manufacturers. In the form of cooperation and mutual benefit, set up the transformer manufacturing center and core processing base in the Middle East, India. Dubai. Vietnam. Thailand. etc.
CANWIN AUTOMATICEQUIPMENT CO.,LTD is a global leading foil winding machine supplier & manufacturer with over 20 years of experiences.Ribbon foil winding machine has unique appearance, convenient operation, intuitive data display, high degree of automation, and is well received by users. This foil winding machine is widely used in oil-immersed transformer, dry transformer, special transformer and reactor production required. Foil coils are of different thicknesses copper or aluminum foil as a conductor, with wide ribbon insulation material as the insulation between layers, with narrow ribbon insulation material as the end insulation, completed winding one time, forming a coil. The inner and outer leads of the coil are welded and wrapped up at the same time.
Oil immersed transformers are the most commonly used equipment mainly because of their simple structure and reliable operation. It has faster heat dissipation, uniform conduction, and better insulation performance than the dry-type transformer.Oil transformers are used in power distribution or electrical substations. Their transformer core and coils are immersed in oil, which cools and insulates. Oil circulates through ducts in the coil and around the coil and core assembly, moved by convection.
Power distribution cabinet transformer is one of the important equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It lowers the network voltage of 10(6)kV or 35kV to 230/400V bus voltage used by users. This kind of product is suitable for AC 50(60)Hz, three-phase maximum rated capacity 2500kVA(single-phase maximum rated capacity 833kVA, generally not recommended to use single-phase transformer), can be used in the indoor (outdoor), the capacity of 315kVA and below can be installed on the rod, the ambient temperature is not higher than 40℃, not less than -25℃, The maximum daily average temperature is 30℃, the maximum annual average temperature is 20℃, the relative humidity is not more than 90%(the ambient temperature is 25℃), and the altitude is not more than 1000m.
The transformer core provides a magnetic path to channel flux. The use of highly permeable material (which describes the material’s ability to carry flux), as well as better core construction techniques, helps provide a desirable, low reluctance flux path and confine lines of flux to the core. An electrical distribution cabinet is a part of an electrical system whose task is to distribute electrical energy. It includes distribution, protection, measurement, control and signaling instruments. The electrical distribution box also contains wires, various types of insulation, and support components. See additional details on canwindg.com
Laser welding machine is an efficient and precise welding method using high energy density laser beam as a heat source. Laser welding is one of the important applications of laser material processing technology. It mainly used for welding thin wall material and low speed in the 1970 s. The welding process is thermal conduction, i.e. the laser radiation heating surface, the surface heat to the internal diffusion through heat conduction, by controlling the width of laser pulse, energy, peak power and repeating frequency, parameters such as melting of components, to form specific molten pool. Because of its unique advantages, it has been successfully used in precision welding of micro and small parts.As one of the best laser welding machine manufacturers in China, Canwin specialized in handheld laser welding machine and wholesale fiber laser welding machine making for over 20 years.
With the development of the times, people’s demand for power supply and the reliability of power supply are increasingly high, so the smart grid has emerged accordingly.In the power system, the core and hub of the substation is the transformer.The function of the transformer is mainly to distribute and convert electric energy. The normal operation of the transformer directly affects the normal function of the substation.The intelligent operation of the transformer mainly involves the protection and status monitoring of the transformer, so as to achieve real-time monitoring of the transformer and ultimately ensure the safety and reliability of power supply.
Insulation level: There are standards for insulation levels. The insulation level of a transformer with a rated high voltage of 35 kV and a rated low voltage of 10 kV is represented as LI200AC85/LI75AC35, where LI200 indicates that the transformer has a high-voltage lightning impulse withstand voltage of 200 kV, a power frequency withstand voltage of 85 kV, and a low-voltage lightning impulse withstand voltage of 75 kV, and a power frequency withstand voltage of 35 kV. The current insulation level of Aux High-Tech Co., Ltd.’s oil-immersed transformer products is LI75AC35, indicating that the transformer has a high-voltage lightning impulse withstand voltage of 75 kV and a power frequency withstand voltage of 35 kV. Because the low voltage is 400 V, it can be ignored.